Installation and Operating Instructions
194 Installation and Use of Accessories
COM Port Assignments
These are the COM port assignments that are expected by Intellex.
Since the internal and external modems have specific port number requirements,
always install the modems before installing the port expanders. Adding the modem
later will result in reassignment of the serial port numbers. Follow this procedure:
Install all modems. Power up the Intellex unit and allow Windows to assign COM
port numbers.
Install the port expander(s). Allow Windows to assign serial port numbers.
Shut down the Intellex unit and restart. The port numbers should be stable after
this.
Connecting Text Sources
Data from a text source will be recorded by Intellex if the following conditions are
met:
The Intellex application must be able to open the COM port.
Serial data must be present for the text stream to be listed in the playback text box.
To set up text recording on the Intellex unit follow these steps:
1. Install all desired serial devices as described above. Be sure to reboot the unit to
minimize the possibility that serial ports may be reassigned the next time the
Intellex unit starts.
2. In the Intellex application, click Setup, then Text. Click Add to set up a text stream
for recording.
COM 1 Not used (disabled in the BIOS)
COM 2 Touch Tracker interface for “MUX” control of Intellex
and dome control from Network Client. On rear of
Intellex unit.
COM 3, COM 4 These COM ports are assigned to either the external
USB modem or the port expanders. The external USB
modem must use COM 3 or COM4 to be used with
pcAnywhere.
COM 5 This COM port is used by the internal modem if it is
installed. If there is no internal modem, it is assigned
to the port expander.
COM 6 and higher Assigned to port expanders.