Installation and Operating Instructions
138 Setup Options
Alarm In Names Tab
Use the Alarm In Names tab to define the name of each alarm input. These names are
used when reviewing alarm images and when searching the image database.
Use the mouse pointer to highlight one of the current alarm input names (1-8). Then
use the virtual keyboard or the physical keyboard (if attached) to enter the new name,
up to 10 characters. The default names are AlarmIn1 through AlarmIn8.
Click OK to accept the displayed alarm input names, as well as any changes on the
other Alarm Setup screens. Click Cancel to cancel the changes. Click Help to display
online help for this screen.
Alarm In Polarity Tab
Use the Alarm In Polarity tab to set the polarity for each of the alarm inputs.
NOTE: The virtual keyboard is disabled on the Alarm In Polarity tab.
1. Click the down arrow for the alarm input. The two polarity options appear.
2. Click the desired alarm input polarity.
Click OK to accept the displayed alarm input polarity settings. Click Cancel to cancel
the changes. Click Help to display online help for this screen.
Alarm Input The names of each alarm input are listed in the Alarm
In Polarity tab. These names are configured in the
Alarm In Names tab.
Polarity Select the desired polarity for this alarm input:
Active-Low or Active-High. That is, select the signal
that triggers an alarm. The default setting is
Active-Low.